Equipment — ทะเบียนอุปกรณ์
66 รายการจาก Training manual (Spare Part List) — Phase 1 report §6, §19 sitemap ข้อ 11
พบ 66 รายการ
| Tag | ชื่ออุปกรณ์ | ประเภท/วัสดุ | Maker : Model / Capacity | จำนวน | Service Life |
|---|---|---|---|---|---|
| P-102A/B | No.1 Wastewater Pump | Self-priming centrifugal, PVDF | TD : GDK-50052, 5HP, 380V/50Hz | 2 sets | 2 ปี |
| P-103 | Wastewater Reserved Pump | Self-priming centrifugal, PVDF | TD : GDK-50052, 50A x240L/min x20mH x3.7kW | 1 set | 2 ปี |
| P-104A/B | Cooling Circulation Pump No.1,2 | Centrifugal, FC | EBARA : 3D 65-125/7.5, 80Ax65Ax1675L/min x20mH x7.5kW | 2 sets | 2 ปี |
| P-109-1A/B | Floatation Pressure Pump | Vertical multi-stage inline, SCS13 | KAWAMOTO : QSBI15-5-M4.0F, 50Ax250L/minx50mHx4.0kW | 2 sets | 2 ปี |
| P-109-2 | Floatation Drain Pump | End suction volute | MITSUWA : 40ESM-F3H, 40Ax80L/minx10mHx1.5kW | 1 set | 2 ปี |
| P-111A/B | Sand Filter Feed Pump | Self-priming centrifugal, FC | KAWAMOTO : GS505ME 3.7, 50Ax50Ax240L/minx35mHx3.7kW | 2 sets | 2 ปี |
| P-114 | Backwash Pump | End suction centrifugal, FC | KAWAMOTO : GEJ805M2 ME 5.5, 80Ax65Ax53m3/hrx20mHx5.5kW | 1 set | 2 ปี |
| P-201A/B | No.2 Wastewater Pump | Self-priming centrifugal, PVDF | TD : GDK-50052, 50Ax120L/minx20mHx3.7kW | 2 sets | 2 ปี |
| P-204 | Treated Water Spray Pump | Self-priming centrifugal, FC | KAWAMOTO : GS505ME 2.2, 50Ax200L/minx25mHx2.2kW | 1 set | 2 ปี |
| P-205A/B | Monitoring Transfer Pump | Self-priming centrifugal, FC | KAWAMOTO : GS655ME 1.5, 80Ax65Ax360L/minx12mHx1.5kW | 2 sets | 2 ปี |
| P-206A/B | Reserved Water Transfer Pump | Submersible, FC | KAWAMOTO : ZUJ-655-1.5T4, 65Ax360L/minx12mHx1.5kW | 2 sets | 2 ปี |
| AP-301 | Slurry Transfer Pump | Air diaphragm, Aluminum | VERDER : VA50AA, 50Ax568L/min@8.4bar | 2 sets | 2 ปี |
| AP-302 | Slurry Tank Pump | Air diaphragm, Aluminum | VERDER : VA50AA, 50Ax568L/min@8.4bar | 1 set | 2 ปี |
| SP-501..504 | Sump Pit Pump No.1-4 | Submersible, Titanium | TSURUMI : 50TM2.75, 50Ax6m3/hrx12mHx0.75kW | 4 sets | 2 ปี |
| CP-401 | 30% Na2S2O3 Feed Pump | Metering diaphragm, PVC | IWAKI LK-55VC-02, 25Ax2.8L/minx5barx0.2kW | 1 set | — |
| CP-402 | PAC Feed Pump | Metering diaphragm, PVC | IWAKI LK-47VC-02, 15Ax1.7L/minx8barx0.2kW | 1 set | — |
| CP-403 | 75% H2SO4 Transfer Pump | Magnetic drive, CFRETFE | IWAKI MX-F251RFVWE-L, 25Ax50L/minx9.4mHx0.75kW | 1 set | — |
| CP-403-1 | 75% H2SO4 Transfer Pump | Metering diaphragm, PVC | IWAKI EH-E36 VC-20EE4, 520mL/minx0.7MPax48W | 1 set | — |
| CP-404-1 | 10% H2SO4 Feed Pump | Metering diaphragm, PVC | IWAKI LK-55VC-02, 25Ax2.8L/minx5barx0.2kW | 1 set | — |
| CP-404-2 | 10% H2SO4 Feed Pump | Metering diaphragm, PVC | IWAKI LK-A65VC-02, 40Ax9L/minx3barx0.4kW | 1 set | — |
| CP-405 | CaCl2 Feed Pump | Metering diaphragm, PVC | IWAKI LK-47VC-02, 15Ax1.7L/minx8barx0.2kW | 1 set | — |
| CP-406-1/2 | NaOH Feed Pump No.1,2 | Metering diaphragm, PVC | IWAKI LK-55VH-02, 25Ax2.8L/minx5barx0.2kW | 2 sets | — |
| AP-407 | Scale Inhibitor Transfer Pump | Air diaphragm, PP | VERDER VA15PP, 15Ax57L/min@7bar | 1 set | — |
| CP-407 | Scale Inhibitor Feed Pump | Metering diaphragm, PVC | IWAKI LK-32VC-02, 15Ax0.5L/minx10barx0.2kW | 1 set | — |
| AP-408 | NaOCl Transfer Pump | Air diaphragm, PP | VERDER VA15PP, 15Ax57L/min@7bar | 1 set | — |
| CP-408 | NaOCl Feed Pump | Metering diaphragm, PVC | IWAKI LK-32VC-02, 15Ax0.5L/minx10barx0.2kW | 1 set | — |
| CP-409-1/2 | Flock (D) Feed Pump | Metering diaphragm, PVC | IWAKI LK-A65VC-04, 40Ax9L/minx3barx0.4kW | 2 sets | — |
| B-01A/B | Aeration Blower | Roots blower, FC | GREATECH : SDB75, 80Ax2.5m3/minx5mAqx3.7kW | 2 sets | — |
| B-02A/B | Mixing Blower | Roots blower, FC | GREATECH : SDB125, 125Ax10m3/minx5mAqx15kW | 2 sets | — |
| A-106 | H2O2 Decomposition Tank Agitator | Vertical, SUS+PE | SUMITOMO gear motor, 242rpm 1.5kW | 1 set | — |
| A-107 | Reaction Tank Agitator | Vertical, SUS+PE | SUMITOMO gear motor, 242rpm 0.75kW | 1 set | — |
| A-108 | Coagulation Tank Agitator | Vertical, SUS | SUMITOMO gear motor, 96.7rpm 0.4kW | 1 set | — |
| A-203 | Neutralization Tank Agitator | Vertical, SUS+PE | SUMITOMO gear motor, 242rpm 0.4kW | 1 set | — |
| A-301 | Slurry Transfer Tank Agitator | Vertical, SUS | SUMITOMO gear motor, 96.7rpm 0.2kW | 1 set | — |
| A-401 | 30% Na2S2O3 Tank Agitator | Vertical, SUS+PE | SUMITOMO gear motor, 242rpm 0.2kW | 1 set | — |
| A-404 | 10% H2SO4 Tank Agitator | Vertical, SUS+PE | SUMITOMO gear motor, 242rpm 0.2kW | 1 set | — |
| A-409 | 0.1% Flock(D) Tank Agitator | Vertical, SUS | SUMITOMO gear motor, 242rpm 0.2kW | 1 set | — |
| M-109 | Floatation (DAF) Driving Unit | — | SM CYCLO CVVM05-6130DC-3045, 0.439rpm, 845Nm, 0.4kW | 1 set | — |
| LCA-102, LCA-201, LCA-302 | Level Switch (Wire type) | — | NOHKEN GW200FWA1, 316SS, L=550mm | 3 sets | — |
| LCA-301 | Level Switch (Wire type) | — | NOHKEN GW200FWA1, L=1000mm | 1 set | — |
| LCA-402, -403, -404, -408 | Level Switch (Radar type) | — | SIEMENS SITRANS LR100, 8m 80GHz | 4 sets | — |
| LCA-111, -114, -204, -205, -206 | Level Switch (Float type) | — | NOHKEN FQ8, 6m PVC cable | 17 sets | — |
| LCA-103 | Level Switch (Float type) | — | NOHKEN FQ6, 6m, 21A 250VAC SPDT | 3 sets | — |
| LCA-104, -401, -407, -405, -406, -409, -501~504 | Level Switch (Electrode rod type) | — | OMRON BF-5, SUS304, 5-pole | 10 sets | — |
| pHIC-106/107/203/205 | pH Meter (Immersion) | — | DKK Electrode No.5600-5F + Transmitter HDM-135A | 4 loops | — |
| pHIC-203-1 | pH Meter (Inline) | — | DKK Electrode No.ELCP11-5F + Transmitter HDM-135A | 1 loop | — |
| ORP-106 | ORP Meter (Immersion) | — | DKK Electrode No.2600-5F + Transmitter HDM-137A | 1 loop | — |
| ORP-102 (w/ TICAR-102) | ORP + Temp Meter (Immersion) | — | DKK Electrode No.2600-5F + Transmitter HBM-162B | 1 loop | — |
| DOI-110 | DO Meter (Immersion) | — | DKK Electrode No.7536L + Transmitter ODM-135A | 1 loop | — |
| ECICAR-205 | Conductivity Meter (Monitoring Tank) | — | DKK Electrode A6-174 + Transmitter WDM-135A, 0-20 uS/cm | 1 loop | — |
| ECICAR-104 | Conductivity Meter (Cooling Tower) | — | DKK Electrode A6-144 + Transmitter WDM-135A | 1 loop | — |
| TICRA-205 / TAR-105 / TA-201 / TA-202-4 / T-105-1..3 / T-202-1..3 | Thermo Controller | — | PS CHINO PT100, No.DB56110000-00A | 11 pcs (รวม) | — |
| FI-104 | Flow Meter (Cooling Pump) | — | +GF+ Variable area 335 DN25, 100-1000 L/hr | 1 set | — |
| FI-109-1 | Flow Meter (Pressure Tank) | — | +GF+ Variable area 335 DN50, 1500-15000 L/hr | 1 set | — |
| FI-114 | Flow Meter (Backwash, Orifice) | — | TOKYO KEISO 0-181WC-125-3N, 14-70 m3/hr | 1 set | — |
| FI-104-1 | Flow Meter (Cooling, Orifice) | — | TOKYO KEISO 0-181WC-100-3N, 14-70 m3/hr | 1 set | — |
| FI-104-2 | Flow Meter (Cooling, Orifice) | — | TOKYO KEISO 0-181WC-050-3N, 6-30 m3/hr | 1 set | — |
| FI-112-1 / FI-113-1 | Flow Meter (Sand/AC Filter, Orifice) | — | TOKYO KEISO 0-181WC-065-3N, 4-20 m3/hr | 2 sets | — |
| FI-110-1 / FI-110-2 | Flow Meter (Aeration air, Orifice) | — | TOKYO KEISO 0-188WC-050-3F, 0.5-3.5 Nm3/hr | 2 sets | — |
| FIQ-102 / FIQ-201 / FIQ-206 | Magnetic Flow Meter | — | SIEMENS SITRANS MAG5100W (FR) | 3 sets | — |
| MV-104/-1/-2 | Automatic Valve (Motorized) | — | KITZ FA10XJMEA-040, 25A/50A/80A | 3 sets | — |
| MV-205-1/-2/-3, MV-206 | Automatic Valve (Motorized) | — | KITZ 10XJMEA-080, 80A | 4 sets | — |
| T-102/103/111/201/206/302 air lines | Constant Air Valve | — | TOKYO KEISO CX1502 series | 6 sets | — |
| HEX-105A/B | Heat Exchanger (Plate type) | — | HISAKA LX195A-TNJ-21, SUS316, 12 m3/hr | 2 sets | — |
| HEX-202 | Heat Exchanger (Plate type) | — | HISAKA LX-015A-TNHJ-11, SUS316, 6 m3/hr | 1 set | — |
| AU-308 | Flock(D) Auto Feed Unit | — | TOHKEMY TAF2-15-S, 0.5-3 g/shot | 1 set | — |